"Failed to transfer command"

Web file generation cannot proceed if the error "Failed to transfer command" occurs.

Cause: EonADT[xx].exe fails to read the .DAT files.

Solution A: Verify that the EonADT[xx].exe process is running in the Windows Task Manager. Try the deployment again.

Solution B: If the problem persists, try the following steps.

Step 1: Terminate the EonADT[xx].exe process in the Windows Task Manager.

Step 2: Delete the application profile in PowerServer Toolkit Configuration.

Step 3: Recreate the application profile and run Appeon Deployment again.

Solution C: If Solution B is unsuccessful, the following actions should rectify it.

Step 1: Delete the application's profile in PowerServer Toolkit Configuration.

Step 2: Delete the entire application folder in the PowerServer Toolkit install directory: \Appeon\PowerServer\Toolkit\Project\ApplicationName.

Step 3: Recreate the Application Profile and run Appeon Deployment again.