"Error launching LoadConfig"

The "Error launching LoadConfig" message is displayed when the user changes the settings in PowerServer Toolkit Configuration or performs Task 2 of the Deploy Wizard.

Cause: There is one of two possibilities that can occur.

1. The EonADT[xx].exe cannot be loaded. This can happen when the developer machine does not meet the minimum hardware requirements specified in Installation Guide for Appeon PowerServer.

2. The EonADT[xx].exe is loaded but fails to read the .DAT files.

Solution A: Follow the steps below to fix the problem.

Step 1: End the EonADT[xx].exe process in the Windows Task Manager

Step 2: Delete the application profile in PowerServer Toolkit Configuration

Step 3: Recreate the application profile and run Appeon Application Deployment/PowerServer Toolkit Configuration.

Solution B: If the problem persists, follow these steps to rectify it.

Step 1: Delete the application profile in PowerServer Toolkit Configuration.

Step 2: Delete the application folder in the PowerServer Toolkit install directory: \Appeon\PowerServer\Toolkit\Project\ApplicationName.

Step 3: Recreate the application profile and run Appeon Application Deployment/PowerServer Toolkit Configuration.