Web file generation cannot proceed if the error "Failed to transfer command" occurs.
Cause: EonADT[xx].exe fails to read the .DAT files.
Solution A: Verify that the EonADT[xx].exe process is running in the Windows Task Manager. Try the deployment again.
Solution B: If the problem persists, try the following steps.
Step 1: Terminate the EonADT[xx].exe process in the Windows Task Manager.
Step 2: Delete the application profile in PowerServer Toolkit Configuration.
Step 3: Recreate the application profile and run Appeon Deployment again.
Solution C: If Solution B is unsuccessful, the following actions should rectify it.
Step 1: Delete the application's profile in PowerServer Toolkit Configuration.
Step 2: Delete the entire application folder in the PowerServer Toolkit install directory: \Appeon\PowerServer\Toolkit\Project\ApplicationName.
Step 3: Recreate the Application Profile and run Appeon Deployment again.