Configuring silent installation for PowerServer

Here are the silent install settings for PowerServer for .NET:

Open the SilentInstall.ini file (located under the root directory of the installation package, e.g. ...\Appeon\SilentInstall.ini) in a text editor and locate the [powerserver] section; and then configure the following parameters for the silent installation of PowerServer for .NET.

Table 1. Silent install settings for .NET

Parameter

Usage

WorkWithAzure

Sets whether to work with the Windows Azure environment.

The value can be true or false.

RegisterNETFramework

Sets whether to register the .NET Framework.

The value can be true or false.

AutoSetEnable32BitAppOnWin64

Sets whether to automatically turn on the Enable32BitAppOnWin64 parameter for IIS.

The value can be true or false.

Upgrade6x

Sets whether to upgrade the PowerServer whose version is lower than 2017, such as 6.5, 6.6, 2013, 2013 R2, and 2015.

The value can be true or false.

CreateWebSite

Sets whether to automatically create a PowerServer Instance on a new Web site.

WebSiteName

Sets the name of the new or an existing IIS Web site where PowerServer will be installed.

WebSiteHome

If CreateWebSite is set to true, you will need to set the home directory for the new IIS Web Site.

WebSitePort

If CreateWebSite is set to true, you will need to set the HTTP Port for the new IIS Web Site.

The value can be between 1 and 65535.

ProcessModelUserName, ProcessModelPassword

Sets the user name and password of an administrator group member for the application pool used by PowerServer. These two parameters must be set in order to install and run PowerServer on Windows Azure successfully.

InstallDemo

Sets whether to install the Appeon demo applications.

The value can be true or false.

SAENGPATH

If InstallDemo is set to true, you will need to specify the path for an existing SQL Anywhere engine.

EnableASAODBCPool

Sets whether to enable the Connection Pooling feature in ODBC Data Source.

The value can be true or false.

AEMUserName, AEMPassword

Sets the AEM login user name and password.

ModifyASPSettings

Sets whether to modify the current ASP.NET settings.

The value can be true or false.

minWorkerThreads, maxIoThreads, minWorkerThreads, minFreeThreads, minLocalRequestFreeThreads, executionTimeout, maxRequestLength

Sets the ASP.NET settings.

Silent_Install_AppPackage

Sets whether to silently install the packaged Appeon application(s) to the PowerServer.

The value can be true or false.

AppPackage_1, AppPackage_2, AppPackage_3, AppPackage_4, AppPackage_5

Points to the folder name of the Appeon application package that will be silently installed to the PowerServer. You can install no more than 5 applications at a time.

To create an Appeon application package, click the Package button on the PowerServer Toolkit and set the package type to Package a Server Deployment Project. For detailed instructions, refer to the section called “Packaging a server deployment project” in PowerServer Toolkit User Guide. After the package is generated, copy the entire package to the "...\Appeon\AppPackage_install" folder and then set the Silent_Install_AppPackage parameter to true and the AppPackage_# parameter to the package folder name.


Here are the silent install settings for PowerServer for JBoss:

Open the SilentInstall.ini file (located under the root directory of the installation package, e.g. ...\Appeon\SilentInstall.ini) in a text editor and locate the [jbossserver] section; and then configure the following parameters for the silent installation of PowerServer for JBoss.

Table 2. Silent install settings for JBoss

Parameter

Usage

JBossPath

Sets the home directory of the JBoss server.

InstanceName

Sets the instance name of the JBoss server. PowerServer will be installed to the specified server instance.

AEMUserName, AEMPassword

Sets the AEM login user name and password.

Upgrade6x

Sets whether to upgrade the PowerServer whose version is lower than 2017, such as 6.5, 6.6, 2013, 2013 R2, and 2015.

The value can be true or false.

JDKHome

Sets the directory where JDK 1.8 or above is located.

Silent_Install_AppPackage

Sets whether to silently install the packaged Appeon application(s) to the PowerServer.

The value can be true or false.

AppPackage_1, AppPackage_2, AppPackage_3, AppPackage_4, AppPackage_5

Points to the folder name of the Appeon application package that will be silently installed to the PowerServer. You can install no more than 5 applications at a time.

To create an Appeon application package, click the Package button on the PowerServer Toolkit and set the package type to Package a Server Deployment Project. For detailed instructions, refer to the section called “Packaging a server deployment project” in PowerServer Toolkit User Guide. After the package is generated, copy the entire package to the "...\Appeon\AppPackage_install" folder and then set the Silent_Install_AppPackage parameter to true and the AppPackage_# parameter to the package folder name.


Here are the silent install settings for PowerServer for JEUS:

Open the SilentInstall.ini file (located under the root directory of the installation package, e.g. ...\Appeon\SilentInstall.ini) in a text editor and locate the [jeusserver] section; and then configure the following parameters for the silent installation of PowerServer for JEUS.

Table 3. Silent install settings for JEUS

Parameter

Usage

JEUSPath

Sets the home directory of the JEUS server.

InstanceName

Sets the name of of the JEUS container. PowerServer will be installed to the specified container.

AEMUserName, AEMPassword

Sets the AEM login user name and password.

Upgrade6x

Sets whether to upgrade the PowerServer whose version is lower than 2017, such as 6.5, 6.6, 2013, 2013 R2, and 2015.

The value can be true or false.

JDKHome

Sets the directory where JDK 1.8 or above is located.

Silent_Install_AppPackage

Sets whether to silently install the packaged Appeon application(s) to the PowerServer.

The value can be true or false.

AppPackage_1, AppPackage_2, AppPackage_3, AppPackage_4, AppPackage_5

Points to the folder name of the Appeon application package that will be silently installed to the PowerServer. You can install no more than 5 applications at a time.

To create an Appeon application package, click the Package button on the PowerServer Toolkit and set the package type to Package a Server Deployment Project. For detailed instructions, refer to the section called “Packaging a server deployment project” in PowerServer Toolkit User Guide. After the package is generated, copy the entire package to the "...\Appeon\AppPackage_install" folder and then set the Silent_Install_AppPackage parameter to true and the AppPackage_# parameter to the package folder name.


To silently install the Appeon application to the PowerServer for JEUS, in addition to configuring the above parameters, you will also need to configure the USERNAME and PASSWORD parameters for a JEUS command in ..\TmaxSoft\JEUS6.0\bin\jeus.properties.cmd.

Here are the silent install settings for PowerServer for WebLogic:

Open the SilentInstall.ini file (located under the root directory of the installation package, e.g. ...\Appeon\SilentInstall.ini) in a text editor and locate the [weblogicserver] section; and then configure the following parameters for the silent installation of PowerServer for WebLogic.

Table 4. Silent install settings for WebLogic

Parameter

Usage

WeblogicPath

Sets the home directory of the WebLogic server.

DomainName

Sets the name of of the WebLogic domain. PowerServer will be installed to the specified domain.

AEMUserName, AEMPassword

Sets the AEM login user name and password.

Upgrade6x

Sets whether to upgrade the PowerServer whose version is lower than 2017, such as 6.5, 6.6, 2013, 2013 R2, and 2015.

The value can be true or false.

JDKHome

Sets the directory where JDK 1.8 or above is located.

Silent_Install_AppPackage

Sets whether to silently install the packaged Appeon application(s) to the PowerServer.

The value can be true or false.

AppPackage_1, AppPackage_2, AppPackage_3, AppPackage_4, AppPackage_5

Points to the folder name of the Appeon application package that will be silently installed to the PowerServer. You can install no more than 5 applications at a time.

To create an Appeon application package, click the Package button on the PowerServer Toolkit and set the package type to Package a Server Deployment Project. For detailed instructions, refer to the section called “Packaging a server deployment project” in PowerServer Toolkit User Guide. After the package is generated, copy the entire package to the "...\Appeon\AppPackage_install" folder and then set the Silent_Install_AppPackage parameter to true and the AppPackage_# parameter to the package folder name.


Here are the silent install settings for PowerServer for WebSphere:

Open the SilentInstall.ini file (located under the root directory of the installation package, e.g. ...\Appeon\SilentInstall.ini) in a text editor and locate the [websphereserver] section; and then configure the following parameters for the silent installation of PowerServer for WebSphere.

Table 5. Silent install settings for WebSphere

Parameter

Usage

WebspherePath

Sets the home directory of the WebSphere server.

AEMUserName, AEMPassword

Sets the AEM login user name and password.

Upgrade6x

Sets whether to upgrade the PowerServer whose version is lower than 2017, such as 6.5, 6.6, 2013, 2013 R2, and 2015.

The value can be true or false.

JDKHome

Sets the directory where JDK 1.8 or above is located.

Silent_Install_AppPackage

Sets whether to silently install the packaged Appeon application(s) to the PowerServer.

The value can be true or false.

AppPackage_1, AppPackage_2, AppPackage_3, AppPackage_4, AppPackage_5

Points to the folder name of the Appeon application package that will be silently installed to the PowerServer. You can install no more than 5 applications at a time.

To create an Appeon application package, click the Package button on the PowerServer Toolkit and set the package type to Package a Server Deployment Project. For detailed instructions, refer to the section called “Packaging a server deployment project” in PowerServer Toolkit User Guide. After the package is generated, copy the entire package to the "...\Appeon\AppPackage_install" folder and then set the Silent_Install_AppPackage parameter to true and the AppPackage_# parameter to the package folder name.