Symptom
When the ASE database password expires, if the PWDialog parameter is set in DBParm, a window will automatically pop up for users to change the password when PowerBuilder runs and connects to the ASE database.
SQLCA.DBParm = "PWEncrypt='Yes',PWDialog=1"
But when users try to change the password, they get the following error:
Environment
PowerBuilder 2017 or later
Cause
This is a known issue in PowerBuilder caused by SQLCA.DBMS=“ASE Adaptive Server Enterprise”.
Solution
You can use the following DMS to connect to the ASE database instead so that you can change the password directly on the pop-up window.
SQLCA.DBMS = "SYC Adaptive Server Enterprise"
After you change the password successfully, we recommend you use this DBMS:
SQLCA.DBMS = "ASE Adaptive Server Enterprise"